LP1K0601BD Schneider Electric Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 6A

LP1K0601BD Schneider Electric Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 6A

Old Price: AED 94.000

New Price: AED 61.000 (35%)

Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 6A, 1 NC aux, 24VDC coil

  • TeSys K is a compact contactor range with a wide variety of coil voltage and terminal connection options
  • The offer features specific versions for railway (TeSys S207) and electrodomestic (TeSys S335) applications
  • One of the smallest contactor offerings in the market

 


 


LP1K0601BD is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 24V DC coil and 1NC auxiliary contact allowing easy integration to all control systems. LP1K0601BD is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 2.2kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it can be easily integrated into all control systems thanks to its 24V DC coil and 1NC built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine). Very compact, 45mm wide, for DIN-rail and panel mounting. Ready for connection to all control systems thanks to a 24V DC control voltage and 1NC built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).

 

 

 


 


 

RangeTeSys
Product or Component TypeContactor
Device short nameLP1K
Contactor applicationMotor control
Utilisation categoryAC-3
AC-3e
AC-4
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit <= 690 V AC <= 400 Hz
Signalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
Control circuit typeDC standard
[Uc] control circuit voltage24 V DC
Motor power kW1.5 kW 220...230 V AC 50/60 Hz AC-3
2.2 kW 380...415 V AC 50/60 Hz AC-3
3 kW 440/690 V AC 50/60 Hz AC-3
1.5 kW 220...230 V AC 50/60 Hz AC-3e
2.2 kW 380...415 V AC 50/60 Hz AC-3e
3 kW 440/690 V AC 50/60 Hz AC-3e
1.5 kW 220...230 V AC 50/60 Hz AC-4
2.2 kW 380...415 V AC 50/60 Hz AC-4
3 kW 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition1 NC
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 140 °F (60 °C)) for power circuit
10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 122 °F (50 °C) - 1 s for power circuit
85 A 122 °F (50 °C) - 5 s for power circuit
80 A 122 °F (50 °C) - 10 s for power circuit
60 A 122 °F (50 °C) - 30 s for power circuit
45 A 122 °F (50 °C) - 1 min for power circuit
40 A 122 °F (50 °C) - 3 min for power circuit
20 A 122 °F (50 °C) - >= 15 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
Associated fuse rating25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit 600 V UL 508
Power circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-5-1
Signalling circuit 600 V UL 508
Power circuit 600 V CSA C22.2 No 14
Signalling circuit 600 V CSA C22.2 No 14
Insulation resistance> 10 MOhm for signalling circuit
Inrush power in W3 W 68 °F (20 °C))
Hold-in power consumption in W3 W 68 °F (20 °C)
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at <122 °F (50 °C))
Drop-out: >= 0.10 Uc (at <122 °F (50 °C))
Connections - terminalsscrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid
screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end
screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid
screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end
Power circuit screw clamp terminals 2 0.002 in² (1.5 mm²)flexible with cable end
Maximum operating rate3600 cyc/h
Auxiliary contacts typeInstantaneous 1 NC
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Mounting SupportRail
Plate
Tightening torque7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2
7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm
Operating time30...40 ms coil energisation and NO closing
10 ms coil de-energisation and NO opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability10 Mcycles
Electrical durability1.3 Mcycles 6 A AC-3 <= 440 V
1.3 Mcycles 6 A AC-3e <= 440 V
0.05 Mcycles 36 A AC-4 <= 440 V
Height2.3 in (58 mm)
Width1.8 in (45 mm)
Depth2.2 in (57 mm)
Net Weight0.496 lb(US) (0.225 kg)
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
Product CertificationsCB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protectionIP2X
Ambient air temperature for operation-13…122 °F (-25…50 °C)
Ambient Air Temperature for Storage-58…176 °F (-50…80 °C)
Operating altitude6561.68 ft (2000 m) without derating
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
CategoryUS10I1222321
Discount Schedule0I12
GTIN3389110363210
ReturnabilityYes
Country of originID
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.60 in (6.600 cm)
Package 1 Width1.89 in (4.800 cm)
Package 1 Length2.44 in (6.200 cm)
Package 1 Weight7.725 oz (219.000 g)
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Height5.91 in (15.000 cm)
Package 2 Width11.81 in (30.000 cm)
Package 2 Length15.75 in (40.000 cm)
Package 2 Weight20.152 lb(US) (9.141 kg)
Unit Type of Package 3P06
Number of Units in Package 3320
Package 3 Height17.72 in (45.000 cm)
Package 3 Width23.62 in (60.000 cm)
Package 3 Length31.50 in (80.000 cm)
Package 3 Weight178.857 lb(US) (81.128 kg)
Warranty18 months

 

 


 