LC1D40ABD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC

LC1D40ABD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC

Old Price: AED 446.000

New Price: AED 398.000 (11%)

IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24VDC coil, open style

  • New modern look & feel of all machines
  • Designed to meet the requirements of industrial and HVAC applications
  • Easier to install and operate with multi-standard screws


 


TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 40A/690V AC-3/3e (18.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

RangeTeSys
TeSys Deca
Range of ProductTeSys Deca
Product or Component TypeContactor
Device short nameLC1D
Contactor applicationResistive load
Motor control
Utilisation categoryAC-4
AC-1
AC-3
AC-3e
Poles description3P
[Ue] rated operational voltagePower circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current60 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
40 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
40 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage24 V DC
Motor power kW18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
11 kW at 220...230 V AC 50/60 Hz (AC-3)
22 kW at 415...440 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
30 kW at 660...690 V AC 50/60 Hz (AC-3)
9 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
11 kW at 220...230 V AC 50/60 Hz (AC-3e)
22 kW at 415...440 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
30 kW at 660...690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 3 phase motors
30 hp at 575/600 V AC 50/60 Hz for 3 phase motors
10 hp at 200/208 V AC 50/60 Hz for 3 phase motors
3 hp at 115 V AC 50/60 Hz for 1 phase motors
30 hp at 460/480 V AC 50/60 Hz for 3 phase motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 140 °F (60 °C)) for signalling circuit
60 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current320 A 104 °F (40 °C) - 10 s for power circuit
720 A 104 °F (40 °C) - 1 s for power circuit
72 A 104 °F (40 °C) - 10 min for power circuit
165 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance1.5 mOhm - Ith 60 A 50 Hz for power circuit
Power dissipation per pole2.4 W AC-3
5.4 W AC-1
2.4 W AC-3e
[Ui] rated insulation voltagePower circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Power circuit 690 V IEC 60947-4-1
Overvoltage categoryIII
pollution degree3
[Uimp] rated impulse withstand voltage6 kV IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability10 Mcycles
Electrical durability0.7 Mcycles 60 A AC-1 <= 440 V
1.5 Mcycles 40 A AC-3 <= 440 V
1.5 Mcycles 40 A AC-3e <= 440 V
Control circuit typeDC standard
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.1...0.3 Uc (-40…158 °F (-40…70 °C)):drop-out DC
0.75...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC
1...1.25 Uc (140…158 °F (60…70 °C)):operational DC
Inrush power in W19 W 68 °F (20 °C))
Hold-in power consumption in W7.4 W 68 °F (20 °C)
Operating time50 ±15 % ms closing
20 ±20 % ms opening
Time constant34 ms
Maximum operating rate3600 cyc/h at 60 °C
Connections - terminalsControl circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end
Power circuit: screw connection 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible without cable end
Power circuit: screw connection 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible without cable end
Power circuit: screw connection 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible with cable end
Power circuit: screw connection 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible with cable end
Power circuit: screw connection 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid without cable end
Power circuit: screw connection 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: solid without cable end
Tightening torqueControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Power circuit 70.8 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.2 in (4 mm)
Power circuit 44.3 lbf.in (5 N.m) EverLink BTR screw connectors 0.002…0.04 in² (1…25 mm²) hexagonal 0.2 in (4 mm)
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typeMechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting SupportRail
Plate
StandardsEN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
CSA C22.2 No 14
UL 60947-4-1
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
IEC 60335-1:Clause 30.2
Product CertificationsCCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC
IP degree of protectionIP20 front face IEC 60529
Protective treatmentTHIEC 60068-2-30
Climatic withstandIACS E10 exposure to damp heat
IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…140 °F (-40…60 °C)
140…158 °F (60…70 °C) with derating
Operating altitude0...9842.52 ft (0...3000 m)
Fire resistance1562 °F (850 °C) IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open 2 Gn, 5...300 Hz)
Vibrations contactor closed 4 Gn, 5...300 Hz)
Shocks contactor closed 15 Gn for 11 ms)
Shocks contactor open 10 Gn for 11 ms)
Height4.8 in (122 mm)
Width2.2 in (55 mm)
Depth4.7 in (120 mm)
Net Weight2.039 lb(US) (0.925 kg)
CategoryUS10I1222358
Discount Schedule0I12
GTIN3389119408486
ReturnabilityYes
Country of originFR
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.44 in (6.200 cm)
Package 1 Width5.39 in (13.700 cm)
Package 1 Length5.98 in (15.200 cm)
Package 1 Weight34.533 oz (979.000 g)
Unit Type of Package 2S02
Number of Units in Package 210
Package 2 Height5.91 in (15.000 cm)
Package 2 Width11.81 in (30.000 cm)
Package 2 Length15.75 in (40.000 cm)
Package 2 Weight22.223 lb(US) (10.080 kg)
Unit Type of Package 3P06
Number of Units in Package 3160
Package 3 Height29.53 in (75.000 cm)
Package 3 Width23.62 in (60.000 cm)
Package 3 Length31.50 in (80.000 cm)
Package 3 Weight395.245 lb(US) (179.280 kg)
Warranty18 months

 

 


 

You may also like

Shopping Bag

Cart Is Empty