LC1D95BD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC
LC1D95BD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC
Old Price: AED 912.000
New Price: AED 850.000 (7%)
IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
- Long durability with high operating rate
- Reliable performance under high environment
- Multi sdandards certified makes it possible to wide application
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 95A/1000V AC-3/AC-3e (45kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V DC coil, 1NO+1NC built-in auxiliary contacts, power connections by screw terminals and control by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, CCC, EAC, Marine). Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 7.32 inches deep. It weighs 5.75 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
| Range | TeSys |
|---|---|
| Range of Product | TeSys Deca |
| Product or Component Type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load Motor control |
| Utilisation category | AC-3 AC-3e AC-4 AC-1 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 Hz |
| [Ie] rated operational current | 95 A (at <140 °F (60 °C)) at <= 440 V AC-3 for power circuit 125 A (at <140 °F (60 °C)) at <= 1000 V AC-1 for power circuit 95 A (at <140 °F (60 °C)) at <= 440 V AC-3e for power circuit |
| [Uc] control circuit voltage | 24 V DC |
| Motor power kW | 25 kW at 220...230 V AC 50 Hz (AC-3) 45 kW at 380...400 V AC 50 Hz (AC-3) 45 kW at 415...440 V AC 50 Hz (AC-3) 55 kW at 500 V AC 50 Hz (AC-3) 45 kW at 660...690 V AC 50 Hz (AC-3) 15 kW at 400 V AC 50 Hz (AC-4) 25 kW at 220...230 V AC 50 Hz (AC-3e) 45 kW at 380...400 V AC 50 Hz (AC-3e) 45 kW at 415...440 V AC 50 Hz (AC-3e) 55 kW at 500 V AC 50 Hz (AC-3e) 45 kW at 660...690 V AC 50 Hz (AC-3e) |
|---|---|
| Maximum Horse Power Rating | 7.5 hp at 120 V AC 60 Hz for 1 phase motors 15 hp at 230/240 V AC 60 Hz for 1 phase motors 30 hp at 200/208 V AC 60 Hz for 3 phase motors 30 hp at 230/240 V AC 60 Hz for 3 phase motors 60 hp at 460/480 V AC 60 Hz for 3 phase motors 60 hp at 575/600 V AC 60 Hz for 3 phase motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 140 °F (60 °C)) for signalling circuit 125 A (at 140 °F (60 °C)) for power circuit |
| Irms rated making capacity | 1100 A at 440 V AC for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 1100 A 104 °F (40 °C) - 1 s for power circuit 800 A 104 °F (40 °C) - 10 s for power circuit 400 A 104 °F (40 °C) - 1 min for power circuit 135 A 104 °F (40 °C) - 10 min for power circuit 140 A - 100 ms for signalling circuit 120 A - 500 ms for signalling circuit 100 A - 1 s for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit |
| Power dissipation per pole | 12.5 W AC-1 7.2 W AC-3 7.2 W AC-3e |
| [Ui] rated insulation voltage | Power circuit 1000 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 |
| Overvoltage category | III |
| pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
| Safety reliability level | B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1 B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical durability | 10 Mcycles |
| Electrical durability | 1.2 Mcycles 95 A AC-3 1.3 Mcycles 125 A AC-1 1.2 Mcycles 95 A AC-3e |
| Control circuit type | DC standard |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.1...0.3 Uc (-40…158 °F (-40…70 °C)):drop-out DC 0.85...1.1 Uc (-40…131 °F (-40…55 °C)):operational DC 1...1.1 Uc (131…158 °F (55…70 °C)):operational DC |
| Inrush power in W | 22 W 68 °F (20 °C)) |
| Hold-in power consumption in W | 22 W 68 °F (20 °C) |
| Operating time | 95...130 ms closing 20...35 ms opening |
| Time constant | 75 ms |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible without cable end Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: flexible without cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible with cable end Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) - cable stiffness: flexible with cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: solid without cable end Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: solid without cable end |
| Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
| Mounting Support | Rail Plate |
| Standards | EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 CSA C22.2 No 14 UL 60947-4-1 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ IEC 60335-1:Clause 30.2 |
|---|---|
| Product Certifications | IECEE CB Scheme CCC EAC LROS (Lloyds register of shipping) RINA BV DNV-GL |
| IP degree of protection | IP20 front face IEC 60529 |
| Protective treatment | THIEC 60068-2-30 |
| Climatic withstand | IACS E10 exposure to damp heat |
| Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C) 140…158 °F (60…70 °C) with derating |
| Operating altitude | 0...9842.52 ft (0...3000 m) |
| Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz) Shocks contactor open 8 Gn for 11 ms) Vibrations contactor closed 3 Gn, 5...300 Hz) Shocks contactor closed 10 Gn for 11 ms) |
| Height | 5.0000000000 in (127 mm) |
| Width | 3.3 in (85 mm) |
| Depth | 7.3 in (186 mm) |
| Net Weight | 5.75 lb(US) (2.61 kg) |
| Category | US10I1222359 |
|---|---|
| Discount Schedule | 0I12 |
| GTIN | 3389110450576 |
| Returnability | Yes |
| Country of origin | CZ |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.33 in (11.000 cm) |
| Package 1 Width | 6.42 in (16.300 cm) |
| Package 1 Length | 8.54 in (21.700 cm) |
| Package 1 Weight | 5.657 lb(US) (2.566 kg) |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 2 |
| Package 2 Height | 5.91 in (15.000 cm) |
| Package 2 Width | 11.81 in (30.000 cm) |
| Package 2 Length | 15.75 in (40.000 cm) |
| Package 2 Weight | 12.004 lb(US) (5.445 kg) |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 32 |
| Package 3 Height | 29.53 in (75.000 cm) |
| Package 3 Width | 23.62 in (60.000 cm) |
| Package 3 Length | 31.50 in (80.000 cm) |
| Package 3 Weight | 215.815 lb(US) (97.892 kg) |
| Warranty | 18 months |
|---|
You may also like
LC1D32N7 Schneider Electric TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 415 V AC coil
LC1D25U7 Schneider Electric TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 250 V AC coil
LC1D18N7 Schneider Electric TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 415 V AC coil
LC1D18U7 Schneider Electric TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 240 V AC coil
LC1D18B7 Schneider Electric TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 24 V AC coil
LC1E65B5 Schneider Electric EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 65A - 24 V AC coil
LC1E50B5 Schneider Electric EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 50A - 24 V AC coil
LC1E40B5 Schneider Electric EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 40A - 24 V AC coil
LC1E3810M5 Schneider EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 38A - 220 V AC coil
GC10040M5 Schneider Electric TeSys GC - modular contactor - 100 A - 4 NO - coil 220...240 V AC
GC6340M5 Schneider Electric TeSys GC - modular contactor - 63 A - 4 NO - coil 220...240 V AC
GC6330M5 Schneider Electric Modular contactor, TeSys GC, AC-7a, 63A, 3NO, 220 to 240V 50Hz coil
GC6320M5 Schneider Electric TeSys GC - modular contactor - 63 A - 2 NO - coil 220...240 V AC
GC4040M5 Schneider Electric TeSys GC - modular contactor - 40 A - 4 NO - coil 220...240 V AC
GC2530M5 Schneider Electric TeSys GC - modular contactor - 25 A - 3 NO - coil 220...240 V AC
GC2510M5 Schneider Electric TeSys GC - modular contactor - 25 A - 1 NO - coil 220...240 V AC
GC1640M5 Schneider Electric TeSys GC - modular contactor - 16 A - 4 NO - coil 220...240 V AC
LP1K0601BD Schneider Electric Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 6A
LC1K0910B7 Schneider Electric Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A
LC1K0901F7 Schneider Electric Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A
LC1K0910M7 Schneider Electric Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A
LC1K0910F7 Schneider Electric Contactor, IEC, TeSys K, 9A, 3 P, 5 HP at 480VAC
LC1K0901M7 Schneider Electric Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A
LC1K0610M7 Schneider Electric Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A
LC1K0610F7 Schneider Electric Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A
LC1DT40M7 Schneider Electric IEC contactor, TeSys Deca, nonreversing, 40A resistive, 4 pole
LC1D95BD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC
LC1D65ABD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC
LC1D50AMD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 50A, 40HP at 480VA
LC1D50ABD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 50A, 40HP at 480VAC
LC1D40ABD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC
LC1D25BD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 25A, 15HP at 480VAC
LC1D18BD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC
LC1D12BD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC
LC1D09MD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC
LC1D09BD Schneider Electric IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC
LC1D32M7 Schneider Electric IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC
LC1D25N7 Schneider Electric IEC contactor, TeSys Deca, nonreversing, 25A, 15HP at 480VAC
LC1D25F7 Schneider Electric IEC contactor, TeSys Deca, nonreversing, 25A, 15HP at 480VAC
LC1D25E7 Schneider Electric IEC contactor, TeSys Deca, nonreversing, 25A, 15HP at 480VAC
LC1D18B7 Schneider Electric IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC
LC1G265KUEN Schneider Electric High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 265A
A9N26924 Schneider Electric Acti 9 - Auxiliary contact OC plus 1 SD and OF ac dc
A9N26929 Schneider Electric Acti 9 - Auxiliary contact OC plus 1 SD and OF ac dc
A9A26927 Schneider Electric Acti 9 -Auxiliary fault contact iSD - 1 C/O - AC/DC
A9A26929 Schneider Electric Acti 9 - Auxiliary contact iOF/SD+OF - 2OC - AC/DC
LC1D38BD Schneider electric TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A
GC4030M5 Schneider electric TeSys GC - modular contactor - 40 A - 3 NO - coil 220...240 V AC
LC1G400KUEN Schneider electric High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 400A