LC1E50M5 Schneider Electric EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 50A - 220 V AC coil

LC1E50M5 Schneider Electric EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 50A - 220 V AC coil

Old Price: AED 299.240

New Price: AED 295.000 (1%)

  • Easy Tesys Control contactor provide a cost-effective solution to a simple application
  • Designed to meet the requirements of Electro domestic and HVAC applications
  • Easier to install and operate with multi-standard screws


EasyPact TVS contactor 3 poles for motor applications up to 50A 30kW@440V. It provides a 220V 50Hz AC coil, without built-in auxiliary contacts, power and control connections by screw clamp terminals. 75mm width for standard operating rates up to 1200 cycles per hour. It procures standard reliability and durability with 0.9 Mcycles electrical durability AC-3 and 5 Mcycles mechanical durability. It can cover -5°C to 55°C working temperature and mounted by DIN-rail, No derating up to 3000m altitude. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current50 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
70 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50 Hz
Motor power kW11 kW at 220/230 V AC 50/60 Hz
22 kW at 380/400 V AC 50/60 Hz
22 kW at 415/440 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
30 kW at 660/690 V AC 50/60 Hz
33 kW at 660...690 V AC 50/60 Hz
Pole contact composition3 NO
[Ith] conventional free air thermal current70 A (at 55 °C) for power circuit
Irms rated making capacity650 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity425 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current400 A 40 °C - 10 s for power circuit
208 A 40 °C - 60 s for power circuit
84 A 40 °C - 600 s for power circuit
Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
100 A gG at <= 690 V coordination type 1 for power circuit
Average impedance1.5 mOhm - Ith 70 A 50 Hz for power circuit
Power dissipation per pole3.8 W AC-3
7.4 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
pollution degree3
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability5000000 cycles
Electrical durability350000 cycles AC-1
900000 cycles AC-3
Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50 Hz
0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA160 VA 50 Hz cos phi 0.75 (at 20 °C)
140 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA15 VA 50 Hz cos phi 0.3 (at 20 °C)
13 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation6…10 W for control circuit
Operating time20...26 ms on closing
8...12 ms on opening
Maximum operating rate1200 cyc/h 60 °C
Connections - terminalsPower circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 5 N.m
Auxiliary contact composition1 NO + 1 NC
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Insulation resistance> 10 MOhm for control circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting supportPlate
DIN rail
StandardsIEC 60947-1
IEC 60947-5-1
IEC 60947-4-1
Product certificationsEAC
CE
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz)
Vibrations contactor closed (3 Gn, 5...300 Hz)
Shocks contactor open (6 Gn for 11 ms)
Shocks contactor closed (7 Gn for 11 ms)
Height127 mm
Width75 mm
Depth114 mm
Product weight0.98 kg
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.200 cm
Package 1 Width12.400 cm
Package 1 Length13.200 cm
Package 1 Weight985.000 g
Unit Type of Package 2S02
Number of Units in Package 29
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.178 kg
Warranty18 months

 

 


 