LC1E120M5 Schneider Electric EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 120A - 220 V AC coil

LC1E120M5 Schneider Electric EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 120A - 220 V AC coil

Old Price: AED 770.210

New Price: AED 768.000 (0%)

  • Easy Tesys Control contactor provide a cost-effective solution to a simple application
  • Designed to meet the requirements of Electro domestic and HVAC applications
  • Easier to install and operate with multi-standard screws


EasyPact TVS contactor 3 poles for motor applications up to 120A 59kW@440V. It provides a 220V 50Hz AC coil, 3NO built-in auxiliary contacts, power and control connections by screw clamp terminals. 120mm width for standard operating rates up to 1200 cycles per hour. It procures standard reliability and durability with 0.8 Mcycles electrical durability AC-3 and 4 Mcycles mechanical durability. It can cover -5°C to 55°C working temperature and mounted by DIN-rail, No derating up to 3000m altitude. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current120 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
96 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
150 A (at <40 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50 Hz
Motor power kW37 kW at 220/230 V AC 50/60 Hz
55 kW at 380/400 V AC 50/60 Hz
59 kW at 415/440 V AC 50/60 Hz
75 kW at 500 V AC 50/60 Hz
80 kW at 660/690 V AC 50/60 Hz
80 kW at 660...690 V AC 50/60 Hz
Pole contact composition3 NO
[Ith] conventional free air thermal current150 A (at 40 °C) for power circuit
Irms rated making capacity1200 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity960 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current1100 A 40 °C - 10 s for power circuit
Associated fuse rating250 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
10 A gG at <= 690 V coordination type 1 for power circuit
Average impedance0.6 mOhm - Ith 150 A 50 Hz for power circuit
Power dissipation per pole8.6 W AC-3
14 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
pollution degree3
[Uimp] rated impulse withstand voltage8 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability4000000 cycles
Electrical durability800000 cycles AC-3
250000 cycles AC-1
Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50 Hz
0.35...0.55 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA300 VA 50 Hz cos phi 0.8 (at 20 °C)
300 VA 60 Hz cos phi 0.8 (at 20 °C)
Hold-in power consumption in VA22 VA 50 Hz cos phi 0.3 (at 20 °C)
22 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation3…8 W for control circuit
Operating time20...50 ms on closing
6...20 ms on opening
Maximum operating rate1200 cyc/h 55 °C
Connections - terminalsPower circuit: screw clamp terminals 1 10…120 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 10…120 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 10…120 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end
Tightening torquePower circuit: 12 N.m
Control circuit: 1.2 N.m
Auxiliary contact composition1 NO + 1 NC
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Insulation resistance> 10 MOhm for control circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting supportDIN rail
Plate
StandardsIEC 60947-5-1
IEC 60947-4-1
IEC 60947-1
Product certificationsEAC
CE
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz)
Vibrations contactor closed (3 Gn, 5...300 Hz)
Shocks contactor open (6 Gn for 11 ms)
Shocks contactor closed (7 Gn for 11 ms)
Height158 mm
Width120 mm
Depth132 mm
Product weight2.3 kg
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.500 cm
Package 1 Width17.500 cm
Package 1 Length21.000 cm
Package 1 Weight2.420 kg
Unit Type of Package 2S06
Number of Units in Package 224
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight70.500 kg
Warranty18 months

 

 


 