This Harmony RM17-UB relay allows monitoring of voltage control in 3-phase networks. This modular multi function 3-phase voltage control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.
| Range of product | Harmony Control Relays |
|---|---|
| Relay type | Voltage control relay |
| Product or component type | 3-phase control relay |
| Product specific application | For 3-phase supply |
| Relay name | RM17UB3 |
| Relay monitored parameters | Overvoltage and undervoltage between phases |
| time delay | Adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault |
| Switching capacity in VA | 1250 VA |
| Measurement range | 220...480 V AC |
| Contacts type and composition | 1 C/O |
| Reset time | 1500 ms time delay |
|---|---|
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 5 A AC/DC |
| Supply voltage limits | 183…528 V AC |
| Power consumption in VA | 0…22 VA at 400 V AC 50 Hz |
| Control circuit frequency | 50...60 Hz +/- 10 % |
| Voltage detection threshold | 183 V |
| Output contacts | 1 C/O |
| nominal output current | 5 A |
| Hysteresis | 2 % |
| Measurement accuracy | +/- 10 % of the full scale value |
| delay at power up | 650 ms |
| Maximum measuring cycle | 150 ms measurement cycle as true rms value |
| Threshold adjustment voltage | 2...20 % of Un selected -2...-17 % in the range 220 V AC +2...+10 % in the range 480 V AC -2...-12 % in the range 208 V AC |
| Repeat accuracy | +/- 0.5 % for input and measurement circuit +/- 1 % for time delay |
| Measurement error | < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation |
| Response time | < 200 ms (in the event of a fault) |
| Quality labels | CE |
| Insulation resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 |
| Operating position | Any position without derating |
| Local signalling | LED (green) for power ON LED (yellow) for relay ON |
| Overvoltage category | III conforming to IEC 60664-1 |
| [Ui] rated insulation voltage | 400 V conforming to IEC 60664-1 |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...2 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Self-extinguishing plastic |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Operating rate | <= 360 operations/hour full load |
| Utilisation category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1 |
| [Un] rated nominal voltage | , self-powered |
| Safety reliability data | B10d = 470000 MTTFd = 502.2 years |
| control type | Without test button |
| Width | 17.5 mm |
| Product weight | 0.08 kg |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
|---|---|
| Ambient air temperature for operation | -20…50 °C |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1 |
| Shock resistance | 5 gn conforming to IEC 60068-2-27 |
| Standards | IEC 60255-1 |
| Product certifications | GOST UL GL C-Tick CSA |
| Ambient air temperature for storage | -40…70 °C |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Directives | 89/336/EEC - electromagnetic compatibility 73/23/EEC - low voltage directive |
| Dielectric test voltage | 2 kV, 1 min AC 50 Hz |
| Non-dissipating shock wave | 4 kV |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.400 cm |
| Package 1 Width | 7.800 cm |
| Package 1 Length | 9.900 cm |
| Package 1 Weight | 87.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.675 kg |
| Warranty | 18 months |
|---|