RM17TU00 Schneider Electric multifunction control relay RM17-TU - range 183..528 V AC

RM17TU00 Schneider Electric multifunction control relay RM17-TU - range 183..528 V AC

Old Price: AED 249.550

New Price: AED 245.500 (2%)

  • Simplified panel design due to 17.5mm width same as 1-pole circuit breaker
  • Experience unprecedented accuracy, predictive maintenance, and superior security.
  • The product monitors its own power supply. When the power supply is abnormal, the output relay de-energizes


This Harmony RM17-TU relay allows monitoring of power supply circuits in 3-phase networks. This modular multi function 3-phase supply control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with screw trimmers. The product monitors its own power supply, when the power supply is abnormal, the output relay de-energizes. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.

Range of productHarmony Control Relays
Relay typeMultifunction control relay
Product or component type3-phase control relay
Relay nameRM17TU
Relay monitored parametersUndervoltage detection
Phase sequence
Phase failure detection
Measurement range208...480 V AC
time delayAdjustable 0.1...10 s, +/- 10 % of the full scale value Tt- time delay upon fault
Output contacts1 C/O
nominal output current5 A
Contacts type and composition1 C/O
[Uc] control circuit voltage208...480 V
Product specific applicationFor 3-phase supply
[Un] rated nominal voltage, self-powered
Supply voltage limits183…528 V AC
Reset time1500 ms time delay
Maximum switching voltage250 V AC
250 V DC
Switching capacity in VA1250 VA
Minimum switching current10 mA at 5 V DC
Maximum switching current5 A AC
5 A DC
Control circuit voltage limits- 12 % + 10 % Un
Power consumption in VA0…22 VA at 400 V AC 50 Hz
Control circuit frequency50...60 Hz +/- 10 %
Measurement voltage limits183…528 V AC
Hysteresis2 %
delay at power up650 ms
Maximum measuring cycle150 ms measurement cycle as true rms value
Threshold adjustment voltage2...20 % of Un selected
-2...-12 % in the range 208 V AC
-2...-17 % in the range 220 V AC
Voltage range208...480 V phase to phase
Repeat accuracy0.5 % for input and measurement circuit
3 % for time delay
Measurement error< 0.05 %/°C with temperature variation
< 1 % over the whole range with voltage variation
Phase failure sensitivity0.7 Un
Response time< 200 ms (in the event of a fault)
Insulation resistance> 500 MOhm at 500 V DC conforming to IEC 60255-5
> 500 MOhm at 500 V DC conforming to IEC 60664-1
[Ui] rated insulation voltage400 V conforming to IEC 60664-1
Supply frequency50/60 Hz +/- 10 %
Operating positionAny position without derating
Connections - terminalsScrew terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Housing materialSelf-extinguishing plastic
Local signallingLED (green) for power ON
LED (yellow) for relay ON
Mounting support35 mm symmetrical DIN rail conforming to IEC 60715
Electrical durability100000 cycles
Mechanical durability30000000 cycles
Operating rate<= 360 operations/hour full load
Utilisation categoryAC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1
AC-14 conforming to IEC 60947-5-1
AC-15 conforming to IEC 60947-5-1
DC-12 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
Safety reliability dataMTTFd = 502.2 years
B10d = 470000
Width17.5 mm
Product weight0.13 kg
control typeWithout test button
Electromagnetic compatibilityEmission standard for industrial environments conforming to IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
Immunity for industrial environments conforming to IEC 61000-6-2
StandardsIEC 60255-1
Product certificationsGL
GOST
UL
C-Tick
CSA
MarkingCE
Directives73/23/EEC - low voltage directive
89/336/EEC - electromagnetic compatibility
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-20…50 °C
Relative humidity95 % at 55 °C conforming to IEC 60068-2-30
Vibration resistance0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6
1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1
Shock resistance15 gn for 11 ms conforming to IEC 60255-21-1
IP degree of protectionIP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Overvoltage categoryIII conforming to IEC 60664-1
Dielectric test voltage2 kV, 1 min AC 50 Hz conforming to IEC 60255-5
2 kV, 1 min AC 50 Hz conforming to IEC 60664-1
Non-dissipating shock wave4 kV conforming to IEC 60255-5
4 kV conforming to IEC 60664-1
4 kV conforming to IEC 61000-4-5
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.800 cm
Package 1 Width8.000 cm
Package 1 Length9.600 cm
Package 1 Weight86.000 g
Unit Type of Package 2S02
Number of Units in Package 248
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight5.003 kg
Warranty18 months

 

 


 