This Harmony RE17L timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 0.7A, is 17.5mm wide and can be supplied with 24V to 240V AC. It also has a solid state output. It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC.

Range of productHarmony Timer Relays
Discrete output typeSolid state
Width17.5 mm
Product or component typeModular timing relay
Component nameRE17L
Time delay range10...100 h
6...60 s
6...60 min
1...10 h
1...10 s
1...10 min
0.1...1 s
nominal output current0.7 A
Height90 mm
Depth72 mm
Control typeSelector switch front panel
[Us] rated supply voltage24...240 V AC 50/60 Hz
Voltage range0.85...1.1 Us
Supply frequency50...60 Hz +/- 5 %
release of input voltage7 V
control signal pulse width0.05 s typical
Insulation resistance100 MOhm at 500 V DC conforming to IEC 60664-1
[Uimp] rated impulse withstand voltage5 kV during 1.2/50 µs
power on delay100 ms
Connections - terminalsScrew terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Dielectric strength2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
Housing materialSelf-extinguishing
Repeat accuracy+/- 0.5 % conforming to IEC 61812-1
Temperature drift+/- 0.05 %/°C
Voltage drift+/- 0.2 %/V
Setting accuracy of time delay+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay typeOff-delay - C- Off-delay relay w/ control signal
Reset time350 ms on de-energisation typical
On-load factor100 %
Power consumption in VA0…3 VA at 240 V AC
Breaking capacity0.5 A AC conforming to UL
0.7 A AC at 20 °C
operating frequency10 Hz
Maximum output current20 A
minimum switching current10 mA
Maximum leakage current5 mA
Maximum switching voltage250 V AC
Maximum voltage drop<4 V 3-wire
<8 V 2-wire
Electrical durability100000000 cycles
MarkingCE
Creepage distance4 kV/3 conforming to IEC 60664-1
Safety reliability dataMTTFd = 353.8 years
B10d = 320000
Mounting positionAny position in relation to normal vertical mounting plane
Mounting support35 mm DIN rail conforming to IEC 60715
Function availableC- Off-delay relay w/ control signal-1 solid state output
control typeWithout test button
Product weight0.068 kg
Time delay typeC
FunctionalityOff-delay timing
Number of functions1
Compatibility codeRE17
Immunity to microbreaks20 ms
Derating factor5 mA/°C
Standards2004/108/EC
IEC 61000-6-3
2006/95/EC
IEC 61000-6-2
IEC 61812-1
IEC 61000-6-4
IEC 61000-6-1
Product certificationsCSA
GL
cULus
Ambient air temperature for storage-30…60 °C
Ambient air temperature for operation-20…60 °C
IP degree of protectionIP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Vibration resistance20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity93 % without condensation conforming to IEC 60068-2-30
Electromagnetic compatibilityElectrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
Conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
Conducted and radiated emissions: , class B, conforming to EN 55022
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.7 cm
Package 1 Width7.8 cm
Package 1 Length9.5 cm
Package 1 Weight71.0 g
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight3.348 kg

 

 


 