RM17UAS15 Schneider Electric voltage control relay RM17-U - range 65..260 V AC
RM17UAS15 Schneider Electric voltage control relay RM17-U - range 65..260 V AC
Old Price: AED 270.630
New Price: AED 266.500 (2%)
- Simplified panel design due to 17.5mm width same as 1-pole circuit breaker
- Experience unprecedented accuracy, predictive maintenance, and superior security.
- Provides automatic shutdown management and fault information for a quick fault identification and troubleshooting
This Harmony RM17-U control relay allows monitoring of voltage control in single phase network. This modular control relay is ideal for monitoring of electrical values and voltage variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.
| Range of product | Harmony Control Relays |
|---|---|
| Relay type | Voltage control relay |
| Product or component type | Voltage control relay |
| Product specific application | For single-phase and DC supply |
| Relay name | RM17UAS |
| Relay monitored parameters | Overvoltage or undervoltage detection |
| time delay | Adjustable 0.1...10 s, 0 + 10 % Tt- time delay upon fault |
| Switching capacity in VA | 1250 VA |
| Measurement range | 65...260 V AC/DC |
| Contacts type and composition | 1 C/O |
| Reset time | 1500 ms time delay |
|---|---|
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 5 A AC/DC |
| Supply voltage limits | 50…270 V AC/DC |
| Power consumption in VA | 0…3 VA AC |
| Maximum power consumption in W | 1 W DC |
| Control circuit frequency | 50...60 Hz +/- 10 % |
| Immunity to microbreaks | 20 ms |
| Output contacts | 1 C/O |
| nominal output current | 5 A |
| Hysteresis | 5…20 % of threshold setting |
| Measurement accuracy | +/- 10 % of the full scale value |
| Polarity | Non reversible polarity on DC supply |
| delay at power up | 1000 ms DC 500 ms AC |
| Maximum measuring cycle | 150 ms measurement cycle as true rms value |
| Repeat accuracy | +/- 0.5 % for input and measurement circuit +/- 1 % for time delay |
| Measurement error | < 1 % over the whole range with voltage variation 0.2 %/°C with temperature variation |
| Quality labels | CE |
| Insulation resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 |
| Operating position | Any position without derating |
| Local signalling | LED (green) for power ON LED (yellow) for relay ON |
| Overvoltage category | III conforming to IEC 60664-1 |
| [Ui] rated insulation voltage | 250 V conforming to IEC 60664-1 400 V conforming to IEC 60664-1 |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...2 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Self-extinguishing plastic |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Operating rate | <= 360 operations/hour full load |
| Utilisation category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1 |
| [Un] rated nominal voltage | , self-powered |
| control type | Without test button |
| Width | 17.5 mm |
| Product weight | 0.08 kg |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
|---|---|
| Ambient air temperature for operation | -20…50 °C |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1 |
| Shock resistance | 5 gn conforming to IEC 60068-2-27 |
| Standards | IEC 60255-6 |
| Product certifications | GL UL GOST CSA C-Tick |
| Ambient air temperature for storage | -40…70 °C |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Directives | 89/336/EEC - electromagnetic compatibility 73/23/EEC - low voltage directive |
| Dielectric test voltage | 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1 |
| Non-dissipating shock wave | 4 kV conforming to IEC 60255-5 4 kV conforming to IEC 60664-1 4 kV conforming to IEC 61000-4-5 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.500 cm |
| Package 1 Width | 7.800 cm |
| Package 1 Length | 10.000 cm |
| Package 1 Weight | 81.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.809 kg |
| Warranty | 18 months |
|---|