XALK178 Schneider electric Harmony XALD, XALK, Control station, plastic, yellow lid, 1 red mushroom push button Ø40

XALK178 Schneider electric Harmony XALD, XALK, Control station, plastic, yellow lid, 1 red mushroom push button Ø40

Old Price: AED 98

New Price: AED 76 (22%)

Harmony XALD, XALK, Control station, plastic, yellow lid, 1 red mushroom push button Ø40

  • Full compatibility with the Ø 22 mm plastic push buttons, switches and pilot lights of the Harmony XB5 range
  • Complete, ready-to-install stations with 1 to 3 buttons for the most common functions
  • Modular system and simple to cable universal range


This Harmony XALK yellow (RAL1021) control station is ideal for a clearly visible emergency shutdown of any machine. This yellow control station enables machine builders to easily add control and signalling functionality on their machines, with permanent modifications or damage to their machine body. It is designed for simple and mass production machines, textiles, packaging, handling small lifting systems, control of garage doors, rolling shutters, smoke extraction vents. It offers emergency stop and emergency switching off functions. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments.

Range of productHarmony XALK
Product or component typeComplete control station
Device short nameXALK
Product destinationFor XB5 Ø 22 mm control and signalling units
Control station applicationEmergency switching off function
Emergency stop function
Colour of base of enclosureLight grey (RAL 7035)
Colour of coverYellow (RAL 1021)
MaterialPolycarbonate
Operator profile1 mushroom head push-button
Operators descriptionRed unmarked 1 NC
ResetTurn to release
Control station composition1 mushroom head Ø 40 mm push-button, red 1 NC unmarked marking
Contact operationSlow-break
Cable entry1 knock-out for cable entry 0…14 mm
2 knock-outs for Pg 13 cable gland and ISO M20 0…12 mm
Net weight0.194 kg
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Positive openingWith conforming to IEC 60947-5-1 appendix K
Operating travel1.5 mm (NC changing electrical state)
2.6 mm (NO changing electrical state)
4.3 mm (total travel)
Operating force44 N NC + NO changing electrical state
Mechanical durability300000 cycles
Connections - terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1
Tightening torque0.8…1.2 N.m conforming to IEC 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA conforming to IEC 60947-5-4
Λ < 10exp(-8) at 17 V, 5 mA conforming to IEC 60947-5-4
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
ambient air temperature for operation-40…70 °C
Overvoltage categoryClass II conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529
IP67
IP69
IP69K
NEMA degree of protectionNEMA 13
NEMA 4X
IK degree of protectionIK03 conforming to IEC 62262
StandardsIEC 60204-1
IEC 60947-1
IEC 60947-5-4
ISO 13850
JIS C 4520
IEC 60364-5-53
IEC 60947-5-5
UL 508
CSA C22.2 No 14
IEC 60947-5-1
Vibration resistance5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.700 cm
Package 1 Width7.000 cm
Package 1 Length7.000 cm
Package 1 Weight161.000 g
Unit Type of Package 2S03
Number of Units in Package 240
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.786 kg
Unit Type of Package 3P06
Number of Units in Package 3320
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight62.788 kg
Warranty18 months