Star-Delta Timing Relay - 0.3s…30s - 24…240V AC/DC - 2C/O

This Harmony RE22 modular single function timer can be set between 1 seconds and 300 hours." "It provides function Qe and it is mountable on DIN rail." "This modular single function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers." "It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device." "It also offers a sealable cover, simple and precise settings with rotary trimmers." "Selectable timing range offers a one stop solution for your power management system." "Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC.

Range of productHarmony Timer Relays
Discrete output typeRelay
Product or component typeModular timing relay
Device short nameRE22
nominal output current8 A
Contacts type and composition2 C/O timed contact, cadmium free
Time delay typeStar-delta
Time delay range0.3...30 s
Control typeRotary knob
Diagnostic button
[Us] rated supply voltage24...240 V AC/DC 50/60 Hz
Release input voltage<= 2.4 V
Voltage range0.85...1.1 Us
Supply frequency50...60 Hz +/- 5 %
Connections - terminalsScrew terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Housing materialSelf-extinguishing
Repeat accuracy+/- 0.5 % conforming to IEC 61812-1
Temperature drift+/- 0.05 %/°C
Voltage drift+/- 0.2 %/V
Setting accuracy of time delay+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay typeStar-delta - Qe-Star-delta relay (1 NC + 1 NO outputs with split common)
Insulation resistance100 MOhm at 500 V DC conforming to IEC 60664-1
Recovery time120 ms on de-energisation
Immunity to microbreaks10 ms
Power consumption in VA3 VA at 240 V AC
Power consumption in W1.5 W at 240 V DC
Switching capacity in VA2000 VA
Minimum switching current10 mA at 5 V DC
Maximum switching current8 A
Maximum switching voltage250 V AC
Electrical durability100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-1
Mechanical durability10000000 cycles
Rated impulse withstand voltage5 kV for 1.2…50 µs conforming to IEC 60664-1
Power on delay100 ms
Creepage distance4 kV/3 conforming to IEC 60664-1
Overvoltage categoryIII conforming to IEC 60664-1
Safety reliability dataB10d = 320000
MTTFd = 353.8 years
Mounting positionAny position
Mounting support35 mm DIN rail conforming to IEC 60715
Status LEDLED backlight green (steady) for dial pointer indication
LED yellow (steady) for output relay energised
LED yellow (fast flashing) for timing in progress and output relay de-energised
LED yellow (slow flashing) for timing in progress and output relay energised
Function availableQe-Star-delta relay (1 NC + 1 NO outputs with split common)-2 C/O
Width22.5 mm
Net weight0.09 kg
control typeWith test button
Number of functions1
Dielectric strength2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1
StandardsIEC 61812-1
UL 508
Directives2006/95/EC - low voltage directive
2004/108/EC - electromagnetic compatibility
Product certificationsCE
CSA
GL
EAC
UL
RCM
CCC
Ambient air temperature for operation-20…60 °C
Ambient air temperature for storage-40…70 °C
IP degree of protectionIP40 housing: conforming to IEC 60529
IP20 terminals: conforming to IEC 60529
IP50 front panel: conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Vibration resistance20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn not operating for 11 ms conforming to IEC 60068-2-27
5 gn in operation for 11 ms conforming to IEC 60068-2-27
Relative humidity95 % at 25…55 °C
Electromagnetic compatibilityFast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3
Conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6
Fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.5 cm
Package 1 Width8.3 cm
Package 1 Length9.6 cm
Package 1 Weight100.0 g
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight4.388 kg
Unit Type of Package 3P06
Number of Units in Package 3640
Package 3 Height80.0 cm
Package 3 Width80.0 cm
Package 3 Length60.0 cm
Package 3 Weight73.38 kg

 

 

 

 

You may also like