METSEPM1125HCL10RS Schneider Electric EasyLogic panel mount meter, class 1, RS485, LED
METSEPM1125HCL10RS Schneider Electric EasyLogic panel mount meter, class 1, RS485, LED
Old Price: AED 495.800
New Price: AED 491.750 (1%)
| Activity | DPLVP |
|---|---|
| Part Number | METSEPM1125HCL10RS |
| Type of measurement | current, voltage, frequency, power factor, phase angle, RPM, peak demand power, harmonic distorsion (I THD & U THD), active power, active energy |
| Accuracy class | class 1 active energy conforming to IEC 62053-21, class 1 reactive energy conforming to IEC 62053-24 |
| Communication port support | screw connector: RS485 |
| Power quality analysis | total harmonic distortion |
| Measurement voltage | 46-277 V AC 50...60 Hz between phase and neutral, 80-480 V AC 50...60 Hz between phases, 277-999000 V AC 50...60 Hz with external VT |
| Sampling rate | 32 samples/cycle |
| Maximum power consumption in W | 2 W at 240 V |
| Frequency measurement range | 45-65 Hz |
| Counter functions | ON hour counting, ON-load hour counting, power interruption |
| Communication of data | reading of measurements, all counters, revolution speed, last cleared log, instantaneous and demand values |
| Tamperproof of settings | protected by access code |
| Measurement current | 5-6000 mA |
| Messages display capacity | 3 fields of 4 characters |
| Refresh time | 1 s |
| Data recording | energy consumption logs |
| Display colour | red |
| Analogue input type | voltage (impedance 5 MOhm)4 x , current 0.005...10 A (impedance 0.3 MOhm)6 x |
| Measurement category | category III 480-480 V |
| Display digits | 12 digit(s) - 14.2 mm in height |
| Metering type | average current Iavg, phase currents, active power P, P1, P2, P3, active, reactive, apparent energy (signed, four quadrant), rotation speed, average voltage Vavg, calculated neutral current, unbalance current, apparent power S, S1, S2, S3, unbalance voltage, frequency, voltage U21, U32, U13, V1, V2, V3, demand power P, Q, S, reactive power Q, Q1, Q2, Q3, power factor and displacement PF (signed, four quadrant), phase current I1, I2, I3 RMS |
| Maximum power consumption in VA | 4 VA at 240 V between phase and neutral |
| Installation category | III |
| standards | IEC 61010-1:ed. 3, UL 61010-1:ed. 3 |
| ambient air temperature for operation | -10-60 °C |
| device application | energy monitoring |
| Communication Port Protocol | Modbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V |
| ambient air temperature for storage | -20-70 °C |
| Type of Installation | indoor installation |
| depth | 13 mm outside: , 49 mm panel: |
| width | 96 mm |
| Display Type | 8 segments LED |
| device short name | PM1125H |
| Targeted Country | all |
| Wire Stripping Length | current circuit: 3.68 mm, voltage circuit: 7 mm, control circuit: 7 mm, 7 mm |
| range | EasyLogic |
| Material | polycarbonate |
| connections - terminals | current circuit: screw clamp terminals (bottom) 2.08-3.31 mm² cable(s) , voltage circuit: screw clamp terminals (top) 0.82-3.31 mm² cable(s) , control circuit: screw clamp terminals (top) 0.82-3.31 mm² cable(s) , communication: screw clamp terminals (bottom) 0.33-3.31 mm² cable(s) |
| tightening torque | current circuit: 0.9-1 N.m Philips No 2 screwdriver , voltage circuit: 0.9-1 N.m Philips No 2 screwdriver , control circuit: 0.9-1 N.m Philips No 2 screwdriver , communication: 0.5-0.6 N.m Philips no 1 screwdriver |
You may also like
VPL12N Schneider Electric Power Factor controller - VarPlus Logic - VPL 12
VPL06N Schneider Electric Power Factor controller - VarPlus Logic - VPL 6
LVR14X00A40T Schneider Electric Anti Harmonic detuned reactor 100kvar 135Hz (2.7) 14% 50Hz 400V
LVR14500A40T Schneider Electric Anti Harmonic detuned reactor 50kvar 135Hz (2.7) 14% 50Hz 400V
LVR14250A40T Schneider Electric Anti Harmonic detuned reactor 25kvar 135Hz (2.7) 14% 50Hz 400V
LVR07X00A40T Schneider Electric Anti Harmonic detuned reactor 100kvar 190Hz (3.8) 7% 50Hz 400V
LVR07500A40T Schneider Electric Anti Harmonic detuned reactor 50kvar 190Hz (3.8) 7% 50Hz 400V
LVR07250A40T Schneider Electric Anti Harmonic detuned reactor 25kvar 190Hz (3.8) 7% 50Hz 400V
LVR07125A40T Schneider Electric Anti Harmonic detuned reactor 12.5kvar 190Hz (3.8) 7% 50Hz 400V
METSEPM5650 Schneider Electric PM5650 Meter, 2 ethernet, up to 63th H, 1,1M, waveform, 4DI/2DO 52 alarms
METSEPM1125HCL10RS Schneider Electric EasyLogic panel mount meter, class 1, RS485, LED
METSEPM1120HCL10RS Schneider Electric EASYLOGIC PM1120H P&E THD RS485 CL 1.0
METSEDM6000HCL 10NC Schneider Electric EASYLOGIC DM6200H VAF PF DPM NONC CL1.0
METSEDM3210 Schneider Electric EasyLogic - Digital Panel Meter DM3000 - Voltmeter - three phases
METSEDM1210 Schneider Electric EasyLogic - Digital Panel Meter DM1000 - Voltmeter - single phase
ABL8WPS24400 Schneider Electric regulated SMPS - 3-phase - 380..500 V - 24 V - 40 A
ABL8WPS24200 Schneider Electric regulated SMPS - 3-phase - 380..500 V AC - 24 V - 20 A
ABL8RPM24200 Schneider Electric regulated SMPS - 1 or 2-phase - 100..240 V - 24 V - 20 A
ABL8RPS24100 Schneider Electric regulated SMPS - 1 or 2-phase - 100..500 V - 24 V - 10 A
ABL8RPS24050 Schneider Electric regulated SMPS - 1 or 2-phase - 100..500 V - 24 V - 5 A
ABL8RPS24030 Schneider Electric regulated SMPS - 1 or 2-phase - 100..500 V - 24 V - 3 A
ABLU3A48200 Schneider Electric Regulated Power Supply, 380...500V AC, 48V, 20A, 3 phases, Universal