ABLU3A48200 Schneider Electric Regulated Power Supply, 380...500V AC, 48V, 20A, 3 phases, Universal

ABLU3A48200 Schneider Electric Regulated Power Supply, 380...500V AC, 48V, 20A, 3 phases, Universal

Old Price: AED 1,968.490

New Price: AED 1,962.250 (0%)

  • One of the most compact on the market
  • Up to +70°C ambiant temperature
  • Manual or Automatic reset in case of output overload or short circuit

 

 


 


This product is part of the Modicon ABL range, an offer of power supplies for industrial use. It is a regulated switch mode power supply. It has a rated input of 380V to 500V AC, a rated output current of 20A at 48V DC and a rated power output of 960W. It supplies direct current voltage and ensures a protection against overloads and short-circuits with automatic or manual restart. The operating temperature for this power supply varies from minus 20°C to plus 70°C. It operates from minus 25 to plus 55degrees celcius and plus 55 to 70degrees celcius with a current derating of 3.3%, at an altitude of less than 2000meters. It measures 124mm high, 110mm wide and mm high. It weighs 1.151kg. This power supply is specially adapted to servos and other DC motor supply and can withstand feedback voltages coming from the motors. This power supply conforms to CB Scheme, cULus Listed, cURus Recognized, RCM, EAC, UKCA and KC certifications, and CE marking. GV2ME07 or GV2RT06 circuit breakers are recommanded for its protection. It installs on 35mm DIN rail. It brings energy to your automated systems. Designed with extreme compactness for simple machines and applications. The ABLU3 Universal power supplies cover power ratings from 72 to 960 W in 24Vdc or 48Vdc and adapt to the majority of power distribution networks used throughout the world.

Range of productModicon Power Supply
Product or component typePower supply
Power supply typeRegulated switch mode
Variant optionUniversal
Enclosure materialMetal
Nominal input voltage380...500 V AC three phase
Rated power in W960 W
Output voltage48 V DC
Power supply output current20 A
Permissible temporary current boost1.5 x In (for 5 seconds)
Input voltage limits320...575 V AC 3 phases
Nominal network frequency50…60 Hz
Network system compatibilityTN
TT
IT
Maximum leakage current2 mA 500 V AC
Input protection typeIntegrated fuse (not interchangeable) 3.15 A
External protection (recommended)
Inrush current35 A at 380 V
35 A at 500 V
Power factor0.90 at 380 V AC
0.90 at 500 V AC
Efficiency95 % at 380 V AC
95 % at 500 V AC
Output voltage adjustment48…56 V
Power dissipation in W49 W
Current consumption< 1.9 A 380 V AC
< 1.7 A 500 V AC
Turn-on time< 2 s
Holding time> 20 ms 380 V AC
> 20 ms 500 V AC
Startup with capacitive loads200000 µF
Residual ripple< 200 mV
Meantime between failure [MTBF]912400 h at 25 °C, full load conforming to SR 332
382500 h at 55 °C, 80 % load conforming to SR 332
Output protection typeAgainst overload and short-circuits, protection technology: manual or automatic reset by switch
Against over temperature, protection technology: automatic reset
Against overvoltage, protection technology: manual reset
Connections - terminalsScrew connection: 4 x 10 mm², (AWG 12...AWG 8) with wire end ferrule for output
Screw connection: 4...16 mm², (AWG 12...AWG 6) without wire end ferrule for output
Screw connection: 0.75…6 mm², (AWG 18...AWG 10) without wire end ferrule for input
Screw connection: 0.75...4 mm², (AWG 18...AWG 12) with wire end ferrule for input
Cage clamp: 0.2...1.5 mm², (AWG 22...AWG 16) without wire end ferrule for diagnostic relay
Cage clamp: 0.2...1.5 mm², (AWG 22...AWG 16) without wire end ferrule for shut down input
Cage clamp: 0.2...0.75 mm², (AWG 22...AWG 18) with wire end ferrule for diagnostic relay
Cage clamp: 0.2...0.75 mm², (AWG 22...AWG 18) with wire end ferrule for shut down input
Line and load regulation< 0.17 % at 100 % load in line at 25 °C
< 0.6 % +/- 0.5 % at 100 % load at 25 °C for single mode
4 % at 150 % load at 25 °C for parallel mode
Status LED1 LED (green and red) product status
Depth128.7 mm
Height124 mm
Width110 mm
Net weight2.29 kg
Output couplingSingle/parallel by switch
MarkingCE
UKCA
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Double-profile DIN rail
SupplySELV conforming to IEC 60950-1
SELV conforming to IEC 60204-1
SELV conforming to IEC 60364-4-41
Dielectric strength4000 V AC with input to output
2000 V AC with input to ground
1500 V AC with output to ground
4000 V AC with input to diagnostic relay
500 V AC with output to diagnostic relay
1500 V AC with diagnostic relay to ground
4000 V AC with shutdown input to input
1500 V AC with shutdown input to ground
with shutdown input not isolated from output
Shutdown inputNon isolated input, dry contact 0.3 mA 4 V
Diagnostic relayElectromechanical relay 1000.0 mA 30 V
Service life10 year(s) 40 °C 80 % load
Overvoltage categoryIII
II
StandardsIEC 62368-1
EN/IEC 61204-3
IEC 61000-6-1
IEC 61000-6-2
IEC 61000-6-3
IEC 61000-6-4
IEC 61000-3-2
EN 61000-3-3
UL 62368-1
CSA C22.2 No 62368-1
CSA C22.2 No 107.1
Product certificationsCE
CUL listed
CUL recognized
RCM
CB Scheme
EAC
KC
UKCA
CURus
Operating altitude< 5000 m overvoltage category III
overvoltage category II
Shock resistance150 m/s² for 11 ms
IP degree of protectionIP20
Ambient air temperature for operation-25…55 °C without current derating mounting position A < 2000 m
55…70 °C with current derating of 3.3 % per °C mounting position A < 2000 m
Electrical shock protection classClass I
pollution degree2
Vibration resistance3.5 mm (f= 3…11.9 Hz) conforming to IEC 60068-2-6
20 m/s² (f= 11.9…150 Hz) conforming to IEC 60068-2-6
Electromagnetic immunityImmunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2
Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2
Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3
Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3
Immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3
Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4
Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5
Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5
Immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6
Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8
Immunity to voltage dips conforming to IEC 61000-4-11
Disturbing field emission conforming to EN 55016-2-3
Limits for harmonic current emissions conforming to IEC 61000-3-2
conforming to EN 55016-1-2
conforming to EN 55016-2-1
Electromagnetic emissionConducted emissions conforming to IEC 61000-6-3
Radiated emissions conforming to IEC 61000-6-4
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.5 cm
Package 1 Width21.0 cm
Package 1 Length22.2 cm
Package 1 Weight3.0 kg
Unit Type of Package 2S03
Number of Units in Package 22
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight6.6 kg

 

 


 

You may also like

51213 Schneider Electric Varlogic PF Controller RT12 step 440V
AED 2,570.790 AED 2,565.750

51213 Schneider Electric Varlogic PF Controller RT12 step 440V

51209 Schneider Electric Varlogic PF Controller RT8 step 440V
AED 2,111.720 AED 2,105.750

51209 Schneider Electric Varlogic PF Controller RT8 step 440V

51207 Schneider Electric varmeter controller - Varlogic - RT6
AED 2,019.910 AED 2,015.750

51207 Schneider Electric varmeter controller - Varlogic - RT6

Shopping Bag