ABLU3A48200 Schneider Electric Regulated Power Supply, 380...500V AC, 48V, 20A, 3 phases, Universal
ABLU3A48200 Schneider Electric Regulated Power Supply, 380...500V AC, 48V, 20A, 3 phases, Universal
Old Price: AED 1,968.490
New Price: AED 1,962.250 (0%)
- One of the most compact on the market
- Up to +70°C ambiant temperature
- Manual or Automatic reset in case of output overload or short circuit
This product is part of the Modicon ABL range, an offer of power supplies for industrial use. It is a regulated switch mode power supply. It has a rated input of 380V to 500V AC, a rated output current of 20A at 48V DC and a rated power output of 960W. It supplies direct current voltage and ensures a protection against overloads and short-circuits with automatic or manual restart. The operating temperature for this power supply varies from minus 20°C to plus 70°C. It operates from minus 25 to plus 55degrees celcius and plus 55 to 70degrees celcius with a current derating of 3.3%, at an altitude of less than 2000meters. It measures 124mm high, 110mm wide and mm high. It weighs 1.151kg. This power supply is specially adapted to servos and other DC motor supply and can withstand feedback voltages coming from the motors. This power supply conforms to CB Scheme, cULus Listed, cURus Recognized, RCM, EAC, UKCA and KC certifications, and CE marking. GV2ME07 or GV2RT06 circuit breakers are recommanded for its protection. It installs on 35mm DIN rail. It brings energy to your automated systems. Designed with extreme compactness for simple machines and applications. The ABLU3 Universal power supplies cover power ratings from 72 to 960 W in 24Vdc or 48Vdc and adapt to the majority of power distribution networks used throughout the world.
Range of product | Modicon Power Supply |
---|---|
Product or component type | Power supply |
Power supply type | Regulated switch mode |
Variant option | Universal |
Enclosure material | Metal |
Nominal input voltage | 380...500 V AC three phase |
Rated power in W | 960 W |
Output voltage | 48 V DC |
Power supply output current | 20 A |
Permissible temporary current boost | 1.5 x In (for 5 seconds) |
Input voltage limits | 320...575 V AC 3 phases |
---|---|
Nominal network frequency | 50…60 Hz |
Network system compatibility | TN TT IT |
Maximum leakage current | 2 mA 500 V AC |
Input protection type | Integrated fuse (not interchangeable) 3.15 A External protection (recommended) |
Inrush current | 35 A at 380 V 35 A at 500 V |
Power factor | 0.90 at 380 V AC 0.90 at 500 V AC |
Efficiency | 95 % at 380 V AC 95 % at 500 V AC |
Output voltage adjustment | 48…56 V |
Power dissipation in W | 49 W |
Current consumption | < 1.9 A 380 V AC < 1.7 A 500 V AC |
Turn-on time | < 2 s |
Holding time | > 20 ms 380 V AC > 20 ms 500 V AC |
Startup with capacitive loads | 200000 µF |
Residual ripple | < 200 mV |
Meantime between failure [MTBF] | 912400 h at 25 °C, full load conforming to SR 332 382500 h at 55 °C, 80 % load conforming to SR 332 |
Output protection type | Against overload and short-circuits, protection technology: manual or automatic reset by switch Against over temperature, protection technology: automatic reset Against overvoltage, protection technology: manual reset |
Connections - terminals | Screw connection: 4 x 10 mm², (AWG 12...AWG 8) with wire end ferrule for output Screw connection: 4...16 mm², (AWG 12...AWG 6) without wire end ferrule for output Screw connection: 0.75…6 mm², (AWG 18...AWG 10) without wire end ferrule for input Screw connection: 0.75...4 mm², (AWG 18...AWG 12) with wire end ferrule for input Cage clamp: 0.2...1.5 mm², (AWG 22...AWG 16) without wire end ferrule for diagnostic relay Cage clamp: 0.2...1.5 mm², (AWG 22...AWG 16) without wire end ferrule for shut down input Cage clamp: 0.2...0.75 mm², (AWG 22...AWG 18) with wire end ferrule for diagnostic relay Cage clamp: 0.2...0.75 mm², (AWG 22...AWG 18) with wire end ferrule for shut down input |
Line and load regulation | < 0.17 % at 100 % load in line at 25 °C < 0.6 % +/- 0.5 % at 100 % load at 25 °C for single mode 4 % at 150 % load at 25 °C for parallel mode |
Status LED | 1 LED (green and red) product status |
Depth | 128.7 mm |
Height | 124 mm |
Width | 110 mm |
Net weight | 2.29 kg |
Output coupling | Single/parallel by switch |
Marking | CE UKCA |
Mounting support | Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 Double-profile DIN rail |
Supply | SELV conforming to IEC 60950-1 SELV conforming to IEC 60204-1 SELV conforming to IEC 60364-4-41 |
Dielectric strength | 4000 V AC with input to output 2000 V AC with input to ground 1500 V AC with output to ground 4000 V AC with input to diagnostic relay 500 V AC with output to diagnostic relay 1500 V AC with diagnostic relay to ground 4000 V AC with shutdown input to input 1500 V AC with shutdown input to ground with shutdown input not isolated from output |
Shutdown input | Non isolated input, dry contact 0.3 mA 4 V |
Diagnostic relay | Electromechanical relay 1000.0 mA 30 V |
Service life | 10 year(s) 40 °C 80 % load |
Overvoltage category | III II |
Standards | IEC 62368-1 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 CSA C22.2 No 62368-1 CSA C22.2 No 107.1 |
---|---|
Product certifications | CE CUL listed CUL recognized RCM CB Scheme EAC KC UKCA CURus |
Operating altitude | < 5000 m overvoltage category III overvoltage category II |
Shock resistance | 150 m/s² for 11 ms |
IP degree of protection | IP20 |
Ambient air temperature for operation | -25…55 °C without current derating mounting position A < 2000 m 55…70 °C with current derating of 3.3 % per °C mounting position A < 2000 m |
Electrical shock protection class | Class I |
pollution degree | 2 |
Vibration resistance | 3.5 mm (f= 3…11.9 Hz) conforming to IEC 60068-2-6 20 m/s² (f= 11.9…150 Hz) conforming to IEC 60068-2-6 |
Electromagnetic immunity | Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 Immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 Immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 Immunity to voltage dips conforming to IEC 61000-4-11 Disturbing field emission conforming to EN 55016-2-3 Limits for harmonic current emissions conforming to IEC 61000-3-2 conforming to EN 55016-1-2 conforming to EN 55016-2-1 |
Electromagnetic emission | Conducted emissions conforming to IEC 61000-6-3 Radiated emissions conforming to IEC 61000-6-4 |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 15.5 cm |
Package 1 Width | 21.0 cm |
Package 1 Length | 22.2 cm |
Package 1 Weight | 3.0 kg |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 2 |
Package 2 Height | 30.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 6.6 kg |