LVR14X00A40T Schneider Electric Anti Harmonic detuned reactor 100kvar 135Hz (2.7) 14% 50Hz 400V

LVR14X00A40T Schneider Electric Anti Harmonic detuned reactor 100kvar 135Hz (2.7) 14% 50Hz 400V

Old Price: AED 9,001.440

New Price: AED 8,997.250 (0%)

  • Low voltage PFC Detuned Reactor for stringent operating condition
  • Detuned reactor for harmonic attenuation
  • Best in class performance, safety and reliability


The VarPlus detuned reactor are designed to protect the capacitor by preventing the amplification of the harmonics present in the system. Capacitors and Reactors are configured in Series resonant circuit. Tuned so that the series resonant frequency is below the lowest harmonic frequency present in the system. This reactor is rated for 100 kVar output power with 2.7/135 Hz tuning order at 400V AC at 50 Hz. Relative impedance, 14 %. This component meet the standards IEC 60068. This component require a forced convection, a fan need to be added. The case dimensions are 350mm in height, 350mm in width and 220mm in depth. For a product weight of 55 kg.

 

 

 


 

RangePowerLogic
Device short nameDR
Product or component typeDetuned reactor
Network frequency50 Hz
Reactive power rating100 kvar for 400 V AC 50 Hz
Network rated voltage400 V AC 50 Hz
Tuning order2.7 - 135 Hz - 14 % - 50 Hz
power losses (max)600 W
Value of inductance0.799 mH
Inductance tolerance- 5 % to 5 % per phase
Fundamental current rating144.3 A
RMS current rating147.2 A
Electrical insulation classClass H
[Ui] rated insulation voltage1.1 kV
Dielectric test voltage4 kV 50 Hz 1 minute
[Imp] maximum permanent current1.12 x I1
Harmonic current spectrum5.5 % x I3
10.7 % x I5
5.3 % x I7
2.1 % x I11
Dynamic withstand current2.2 x Isc
[Ith] conventional free air thermal current2 A at 250 V AC 50 Hz
Type of installationIndoor installation
type of coolingForced convection
Connections - terminalsPad terminal
fixing center200 x 125 mm
Height350 mm
Width350 mm
Depth220 mm
Net weight55 kg
StandardsIEC 60068
IP degree of protectionIP00
Operating altitude<= 2000 m
Ambient air temperature for operation0…55 °C at <= 1000 m
0…50 °C at > 1000...2000 m
Average ambient air temperature for operation50 °C at <= 1000 m (average over 24 hours)
40 °C at <= 1000 m (average over 1 year)
45 °C at > 1000...2000 m (average over 24 hours)
35 °C at > 1000...2000 m (average over 1 year)
Climatic withstandRelative humidity: 20...80 %
Salt mist (400 V/50 Hz) : 250 hours
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height41.0 cm
Package 1 Width35.5 cm
Package 1 Length55.0 cm
Package 1 Weight62.0 kg
Unit Type of Package 2P06
Number of Units in Package 22
Package 2 Height50.0 cm
Package 2 Width80.0 cm
Package 2 Length60.0 cm
Package 2 Weight132.5 kg

 

 


 

You may also like

51213 Schneider Electric Varlogic PF Controller RT12 step 440V
AED 2,570.790 AED 2,565.750

51213 Schneider Electric Varlogic PF Controller RT12 step 440V

51209 Schneider Electric Varlogic PF Controller RT8 step 440V
AED 2,111.720 AED 2,105.750

51209 Schneider Electric Varlogic PF Controller RT8 step 440V

51207 Schneider Electric varmeter controller - Varlogic - RT6
AED 2,019.910 AED 2,015.750

51207 Schneider Electric varmeter controller - Varlogic - RT6

Shopping Bag

Cart Is Empty