LVR07500A40T Schneider Electric Anti Harmonic detuned reactor 50kvar 190Hz (3.8) 7% 50Hz 400V

LVR07500A40T Schneider Electric Anti Harmonic detuned reactor 50kvar 190Hz (3.8) 7% 50Hz 400V

Old Price: AED 3,801.100

New Price: AED 3,798.000 (0%)

  • Low voltage PFC Detuned Reactor for stringent operating condition
  • Detuned reactor for harmonic attenuation
  • Best in class performance, safety and reliability


The VarPlus detuned reactor are designed to protect the capacitor by preventing the amplification of the harmonics present in the system. Capacitors and Reactors are configured in Series resonant circuit. Tuned so that the series resonant frequency is below the lowest harmonic frequency present in the system. This reactor is rated for 50 kVar output power with 3.8/190 Hz tuning order at 400V AC at 50 Hz. Relative impedance, 7 %. This component meet the standards IEC 60068. This component require a forced convection, a fan need to be added. The case dimensions are 270mm in height, 260mm in width and 200mm in depth. For a product weight of 22 kg.

 

 

 


 

RangePowerLogic
Device short nameDR
Product or component typeDetuned reactor
Network frequency50 Hz
Reactive power rating50 kvar for 400 V AC 50 Hz
Network rated voltage400 V AC 50 Hz
Tuning order3.8 - 190 Hz - 7 % - 50 Hz
power losses (max)320 W
Value of inductance0.75 mH
Inductance tolerance- 5 % to 5 % per phase
Fundamental current rating72.2 A
RMS current rating77.9 A
Electrical insulation classClass H
[Ui] rated insulation voltage1.1 kV
Dielectric test voltage4 kV 50 Hz 1 minute
[Imp] maximum permanent current1.2 x I1
Harmonic current spectrum3.7 % x I3
38.2 % x I5
13.6 % x I7
4.9 % x I11
Dynamic withstand current2.2 x Isc
[Ith] conventional free air thermal current2 A at 250 V AC 50 Hz
Type of installationIndoor installation
type of coolingForced convection
Connections - terminalsPad terminal
fixing center200 x 125 mm
Height270 mm
Width260 mm
Depth200 mm
Product weight22 kg
StandardsIEC 60068
IP degree of protectionIP00
Operating altitude<= 2000 m
Ambient air temperature for operation0…55 °C at <= 1000 m
0…50 °C at > 1000...2000 m
Average ambient air temperature for operation50 °C at <= 1000 m (average over 24 hours)
40 °C at <= 1000 m (average over 1 year)
45 °C at > 1000...2000 m (average over 24 hours)
35 °C at > 1000...2000 m (average over 1 year)
Climatic withstandRelative humidity: 20...80 %
Salt mist (400 V/50 Hz) : 250 hours
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height53.0 cm
Package 1 Width40.0 cm
Package 1 Length60.0 cm
Package 1 Weight35.25 kg
Unit Type of Package 2P06
Number of Units in Package 22
Package 2 Height70.0 cm
Package 2 Width60.0 cm
Package 2 Length80.0 cm
Package 2 Weight75.5 kg

 

 


 

You may also like

51213 Schneider Electric Varlogic PF Controller RT12 step 440V
AED 2,570.790 AED 2,565.750

51213 Schneider Electric Varlogic PF Controller RT12 step 440V

51209 Schneider Electric Varlogic PF Controller RT8 step 440V
AED 2,111.720 AED 2,105.750

51209 Schneider Electric Varlogic PF Controller RT8 step 440V

51207 Schneider Electric varmeter controller - Varlogic - RT6
AED 2,019.910 AED 2,015.750

51207 Schneider Electric varmeter controller - Varlogic - RT6

Shopping Bag

Cart Is Empty