ATS430D75S6 Schneider Electric Soft starter, Altivar Soft Starter ATS430, 75A, 208 to 600V AC, control supply 110 to 230V AC

ATS430D75S6 Schneider Electric Soft starter, Altivar Soft Starter ATS430, 75A, 208 to 600V AC, control supply 110 to 230V AC

Old Price: AED 5,053.440

New Price: AED 5,011.250 (1%)

  • Reduce time (design to operation) and overall cost
  • Improved sustainability (enviromental performance, durability and efficiency)
  • Reduced operational expenditure (high durability)

 


 

Range of productAltivar Soft Starter ATS430
Product or component typeSoft starter
Product destinationAsynchronous motors
Product specific applicationStandard industrial machines
Device short nameATS430
Network number of phases3 phases
Utilisation categoryAC-3A
AC-53A
Ue power supply voltage208...600 V AC (- 15...10 %)
power supply frequency50...60 Hz - 20...20 %
[Ie] rated operational currentNormal duty: 75 A in line (at <40 °C)
Service factor at Ie100
Torque controlTrue
IP degree of protectionIP20
Motor power kW18.5 kW at 230 V in line normal duty
37 kW at 400 V in line normal duty
37 kW at 440 V in line normal duty
45 kW at 500 V in line normal duty
45 kW at 525 V in line normal duty
Motor power hp20 hp at 208 V normal duty
25 hp at 230 V normal duty
50 hp at 460 V normal duty
60 hp at 575 V normal duty
Communication port protocolModbus serial
Device connectionIn line
Overload current400 % Ie for 13 s
On-load factor50 %
Operating cycles/hour10 cyc/h
[Us] control circuit voltage110...230 V AC 50...60 Hz - 15...10 %
Apparent power70 VA
Integrated motor overload protectionTrue
motor thermal protection classClass 10E
Protection typePhase failure: mains
Thermal protection: mains
Thermal protection: starter
Current overload: motor
Motor underload: motor
Excessive acceleration time: motor
Motor phase loss detection: motor
Protection against line phase inversion: mains
External thermal protection: motor
Short-circuit between motor phase and earth: motor
current limiting %In (5 x Ie maximum)150…700 %
Rated current pwr loss specification75 A
Power loss static current independent19 W
Power loss per device current dependent8 W
Power loss during starting640 W during starting at 40 °C at 400% In
StandardsEN/IEC 60947-4-2
UL 60947-4-2
IEC 60664-1
Product certificationscULus
CE
UKCA
CCC
RCM
EAC
KC
MarkingCULus
CE
UKCA
CCC
RCM
EAC
KC
[Uc] control circuit voltage24 V DC
Discrete input number4
Discrete input type(STOP) digital input, 4.4 kOhm
(RUN) digital input, 4.4 kOhm
(DI3) digital input, 4.4 kOhm
(DI4) digital input, 4.4 kOhm
Input compatibilitySTOP: digital input level 1 PLC conforming to EN/IEC 61131-2
RUN: digital input level 1 PLC conforming to EN/IEC 61131-2
DI3: digital input level 1 PLC conforming to EN/IEC 61131-2
DI4: digital input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logicDigital input STOP at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
Digital input RUN at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
Digital input DI3 at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
Digital input DI4 at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
Relay output number2
Relay output typeRelay outputs R1A, R1C NO
Relay outputs R1B, R1C NC
Relay outputs R2A, R2C NO
Minimum switching current100 mA at 12 V DC for relay outputs
Maximum switching currentRelay outputs 2 A / 250 V AC for AC-15 100000 cycles following IEC 60947-5-1
Relay outputs 2 A / 30 V DC for DC-13 150000 cycles following IEC 60947-5-1
Analogue input number1
Analogue input typePTC1 : PTC temperature probe
PTC2 : PTC temperature probe
Analogue output number1
Analogue output typeCurrent output AQ1 : 0...20 mA/4...20 mA , impedance< 500 Ohm
Voltage output AQ1 : 0...10 V , impedance> 470 Ohm
Communication port protocolModbus serial RJ45
Modbus serial open style (DO, D1, PE, COM)
Connector type1 RJ45
Open style
Physical interface2-wire RS 485 - connector(s): RJ45
2-wire RS 485 - connector(s): open style (DO, D1, PE, COM)
Transmission frameRTU : 1 RJ45
RTU : open style (DO, D1, PE, COM)
Transmission rate4.8…38.4 kbps for Modbus serial RJ45
0.3...115.2 kbps for Modbus serial open style (DO, D1, PE, COM)
Data format8 bits, odd, even or no parity, 1 or 2 bits to stop for Modbus serial RJ45
8 bits, configurable odd, even or no parity for Modbus serial open style (DO, D1, PE, COM)
Number of addresses0…247 for Modbus serial
Method of accessSlave Modbus serial
Type of polarizationNo impedance for Modbus serial
Display screen availableTrue
Operating positionVertical +/- 10 degree
Height283 mm
Width160 mm
Depth230.2 mm
Net weight6.60 kg
internal bypassTrue
Function availableSingle direction
Pre-heating
Power monitoring
Condition monitoring
User management
Ports and services hardening
Security event logging
Cybersecure firmware update
Small motor test
material declarationTrue
Electromagnetic compatibilityConducted and radiated emissions level A conforming to IEC 60947-4-2
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Damped oscillating waves level 3 conforming to IEC 61000-4-18
Immunity to conducted disturbances radio-frequency level 3 conforming to IEC 61000-4-6
pollution degreeLevel 3
[Uimp] rated impulse withstand voltage6 kV
[Ui] rated insulation voltage600 V
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3
Class 3S3 according to IEC 60721-3-3
Ambient air temperature for operation-25…40 °C (without derating)
40…60 °C (with current derating of 1 % per °C above 40 °C)
Ambient air temperature for storage-40…70 °C
Ambient air transport temperature-40…70 °C
Operating altitude<= 2000 m without derating
> 2000...4800 m with current derating 1 % per 100 m above 2000 m
Relative humidity5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
Maximum deflection under vibratory load (during storage)1.75 mm at 2...9 Hz
Maximum deflection under vibratory load (during transport)1.75 mm at 2...9 Hz
Maximum acceleration under vibrational stress (during operation)1 gn at 13…200 Hz
Maximum acceleration under vibratory load (during storage)1 gn at 9…200 Hz
1.5 gn at 200…500 Hz
Maximum acceleration under vibratory load (during transport)1 gn at 9…200 Hz
1.5 gn at 200…500 Hz
Maximum acceleration under shock impact (during operation)15 gn at 11 ms
Maximum acceleration under shock load (during storage)10 gn at 11 ms
Maximum acceleration under shock load (during transport)10 gn at 11 ms
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height28.000 cm
Package 1 Width23.500 cm
Package 1 Length36.000 cm
Package 1 Weight7.448 kg
Unit Type of Package 2S06
Number of Units in Package 28
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight70.500 kg

 


 