ATS130N2D38LT Schneider Electric Altivar Soft Starter ATS130, 38A, 200 to 480V AC, control supply 24V DC

ATS130N2D38LT Schneider Electric Altivar Soft Starter ATS130, 38A, 200 to 480V AC, control supply 24V DC

Old Price: AED 2,824.200

New Price: AED 2,791.000 (1%)

  • Allows design optimization and time savings
  • Optimized motor management (with TeSys Deca motor circuit breaker)
  • Preventive maintenance free


This soft starter belongs to the Altivar Soft Starter ATS130 range that is intended to start and stop asynchronous motors supplied from 200 to 480V. With an operational rated current of 38A in normal duty, it supplies motor from 11 to 22kW according to mains voltage. Compact, it provides mechanical and electrical flexibility in control panel design. ATS130 is preventive maintenance free and allows optimized motor management especially in combination with TeSys Deca motor circuit breaker. It is designed with Everlink power terminals and spring control terminals that avoid annual wire retightening. This soft starter has the same width (55mm) as the TeSys Deca frame 3 motor circuit breaker; it allows the building of the ATS130 Soft Motor Starter. Its dimensions are 55mm (width) x 165mm (depth) x 179mm (height), and it weighs 1.26kg. Altivar Soft Starter ATS130 is designed to address pumps, fans, compressors, conveyors, and other simple machines. It conforms to the IEC/EN60947-4-1 standard and has received the CE, EAC, UKCA, CCC, and RCM certifications. It is possible to add a fixing kit to mount the TeSys Deca frame 3 motor circuit breaker on top of ATS130 or a cooling fan to extend the number of starts per hour. The ATS130 soft starters can be mounted on a backplate or on a DIN rail, side by side, and they are compatible with a 200mm depth cabinet. The Altivar Soft Starter ATS130 range is preventive maintenance-free and increases operational efficiency during design, manufacturing, and commissioning. Ecolabel Green Premium compliant, this range is designed to take environmental considerations beyond current directives and regulations, compliant with RoHS and REACH.

Range of productAltivar Soft Starter ATS130
Product or component typeSoft starter
Product destinationAsynchronous motors
Product specific applicationSimple machine
Device short nameATS130
Network number of phases3 phases
Utilisation categoryAC-53A
Ue power supply voltage200...480 V - 15...10 %
power supply frequency50...60 Hz +/- 5 Hz
[Ie] rated operational current38 A in line (at <40 °C)
Service factor at Ie100
Torque controlFalse
IP degree of protectionIP20
Motor power kW11 kW at 230 V normal duty
18.5 kW at 400 V normal duty
22 kW at 440 V normal duty
Motor power hp10 hp at 200 V normal duty
10 hp at 208 V normal duty
10 hp at 230 V normal duty
25 hp at 460 V normal duty
Overload current profile300 % Ie for 5 s
On-load factor70 %
Operating cycles/hour50 cyc/h
Minimum motor current20 % Ie
Device connectionIn line
[Us] control circuit voltage24 V DC +/- 10 %
Control power21.6 W starting and stopping
3 W steady state
Integrated motor overload protectionFalse
Protection typePhase failure: mains
Thermal protection: starter
Bypass error: starter
Control voltage Us: starter
Rated current pwr loss specification38.0 A
Power loss static current independent3 W
Power loss per device current dependent7 W
Power loss during starting220 W 300 % Ie
StandardsEN/IEC 60947-4-2
UL 60947-4-2
IEC 60664-1
Product certificationsCE
UKCA
CCC
RCM
EAC
UL
MarkingCE
CCC
UKCA
RCM
EAC
[Uc] control circuit voltage24 V DC
Discrete input number3
Discrete input type(DI) digital input, 10 kOhm
(DI2) digital input, 10 kOhm
(BOOST) digital input, 10 kOhm
Input compatibilityDiscrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logicDigital input at State 0: 0...< 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA
Relay output number1
Relay output typeRelay outputs R1A, R1C NO
Minimum switching current2.5 mA at 24 V DC for relay outputs
Maximum switching currentOn resistive load for relay outputs : 1 A 250 V AC 400000 cycles
On resistive load for relay outputs : 1 A 30 V DC 400000 cycles
On inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cycles
On inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles
Discrete output number1
Discrete output typeNon programmable digital output DQ1 <= 30 V 200 mA
Display type1 LED (green) for control power energized
1 LED (yellow and red) for motor operation phases, errors
Display screen availableFalse
Operating positionVertical +/- 30 degree
Height166 mm
Width55 mm
Depth165 mm
Net weight1.3 kg
Suitable for mounting onto standard railsTrue
Function availableDeceleration voltage ramp
Boost
internal bypassTrue
material declarationTrue
pollution degreeLevel 2
environmental class (during operation)Without salt mist: 3C3 conforming to IEC 60721-3-3
3S3 conforming to IEC 60721-3-3
[Uimp] rated impulse withstand voltage4 kV
[Ui] rated insulation voltage480 V
Electromagnetic compatibilityConducted and radiated emissions level B conforming to IEC 60947-4-2
Short voltage interruptions level 3 conforming to IEC 61000-4-11
Electrostatic discharge level 2 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 1 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 2 conforming to IEC 61000-4-4
Oscillatory waves immunity level 3 conforming to IEC 61000-4-12
Voltage/current impulse level 2 conforming to IEC 61000-4-5
Conducted disturbances, induced by radiofrequency fields level 1 conforming to IEC 61000-4-6
Ambient air temperature for operation-10…40 °C (without derating)
40…60 °C (with current derating 1.5 % per °C)
Ambient air temperature for storage-25…70 °C
Ambient air transport temperature-40…70 °C
Operating altitude0...1000 m without derating
1000...4000 m 1 % per 100 m
Relative humidity5…95 % non condensing without dripping water conforming to IEC 60068-2-3
Maximum acceleration under vibrational stress (during operation)10 m/s² at 9...200 Hz
Maximum acceleration under vibratory load (during storage)10 m/s² at 9...200 Hz
Maximum acceleration under vibratory load (during transport)10 m/s² at 9...200 Hz
Maximum deflection under vibratory load (during operation)3 mm at 2-9 Hz
Maximum deflection under vibratory load (during storage)3 mm at 2-9 Hz
Maximum deflection under vibratory load (during transport)3 mm at 2-9 Hz
Maximum acceleration under shock impact (during operation)100 m/s² at 11 ms
Maximum acceleration under shock load (during storage)100 m/s² at 11 ms
Maximum acceleration under shock load (during transport)100 m/s² at 11 ms
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.300 cm
Package 1 Width27.000 cm
Package 1 Length27.500 cm
Package 1 Weight1.516 kg
Unit Type of Package 2S06
Number of Units in Package 240
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight69.500 kg

 


 