This soft starter belongs to the Altivar Soft Starter ATS430 range which is intended to smoothly start and stop asynchronous motors supplied from 208 to 600V. With an operational rated current of 210A, it supplies motor from 55 to 132kW according to mains voltage. With an efficiency rating of 99.5%, torque control, high stress resistance, and complete monitoring, the ATS430 provides the essentials for effectiveness. Altivar Soft Starter ATS430 delivers best in class motor control with its torque control, the original by Schneider Electric. ATS430 provides complete system monitoring, including the motor, application, power and energy with an accuracy greater than 95%. The cybersecurity standards for ATS430 are met by incorporating best practices that help minimize downtime. Dimensions are 206mm (width), 261mm (depth), 443mm (height) and it weighs 14.6kg. ATS430 uses plastic with more than 20% bio-based content, and aluminum is ASI-certified. Altivar Soft Starter ATS430 is designed for applications such as pumps, fans, compressors, conveyors, and mixers. It conforms to IEC/EN 60947-4-2 and has received CE, cULus, UKCA, RCM, and CCC certifications. Some accessories are available, including an IP65 or IP43 remote mounting kit for installing a plain text or graphic display terminal on the enclosure door. The packaging is made from recycled cardboard and incorporates less single-use plastic. The ATS430 soft starters shall be mounted vertically inside an enclosure. The Altivar Soft Starter ATS430 range offers torque control, reliable operation, and simplicity. It also integrates essential features for the future, including cybersecurity best practices and condition monitoring. ATS430 delivers the essentials for effectiveness while lowering the overall equipment costs.
Range of product | Altivar Soft Starter ATS430 |
---|---|
Product or component type | Soft starter |
Product destination | Asynchronous motors |
Product specific application | Standard industrial machines |
Device short name | ATS430 |
Network number of phases | 3 phases |
Utilisation category | AC-3A AC-53A |
Ue power supply voltage | 208...600 V AC (- 15...10 %) |
power supply frequency | 50...60 Hz - 20...20 % |
[Ie] rated operational current | Normal duty: 210 A in line (at <40 °C) |
Service factor at Ie | 100 |
Torque control | True |
IP degree of protection | IP00 |
Motor power kW | 55 kW at 230 V in line normal duty 110 kW at 400 V in line normal duty 110 kW at 440 V in line normal duty 132 kW at 500 V in line normal duty 132 kW at 525 V in line normal duty |
Motor power hp | 60 hp at 208 V normal duty 75 hp at 230 V normal duty 150 hp at 460 V normal duty 200 hp at 575 V normal duty |
Communication port protocol | Modbus serial |
Device connection | In line |
---|---|
Overload current | 400 % Ie for 13 s |
On-load factor | 50 % |
Operating cycles/hour | 10 cyc/h |
[Us] control circuit voltage | 110...230 V AC 50...60 Hz - 15...10 % |
Apparent power | 70 VA |
Integrated motor overload protection | True |
motor thermal protection class | Class 10E |
Protection type | Phase failure: mains Thermal protection: mains Thermal protection: starter Current overload: motor Motor underload: motor Excessive acceleration time: motor Motor phase loss detection: motor Protection against line phase inversion: mains External thermal protection: motor Short-circuit between motor phase and earth: motor |
current limiting %In (5 x Ie maximum) | 150…700 % |
Rated current pwr loss specification | 210 A |
Power loss static current independent | 19 W |
Power loss per device current dependent | 35 W |
Power loss during starting | 1763 W during starting at 40 °C at 400% In |
Standards | EN/IEC 60947-4-2 UL 60947-4-2 IEC 60664-1 |
Product certifications | cULus CE UKCA CCC RCM EAC KC |
Marking | CULus CE UKCA CCC RCM EAC KC |
[Uc] control circuit voltage | 24 V DC |
Discrete input number | 4 |
Discrete input type | (STOP) digital input, 4.4 kOhm (RUN) digital input, 4.4 kOhm (DI3) digital input, 4.4 kOhm (DI4) digital input, 4.4 kOhm |
Input compatibility | STOP: digital input level 1 PLC conforming to EN/IEC 61131-2 RUN: digital input level 1 PLC conforming to EN/IEC 61131-2 DI3: digital input level 1 PLC conforming to EN/IEC 61131-2 DI4: digital input level 1 PLC conforming to EN/IEC 61131-2 |
Discrete input logic | Digital input STOP at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Digital input RUN at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Digital input DI3 at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Digital input DI4 at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
Relay output number | 2 |
Relay output type | Relay outputs R1A, R1C NO Relay outputs R1B, R1C NC Relay outputs R2A, R2C NO |
Minimum switching current | 100 mA at 12 V DC for relay outputs |
Maximum switching current | Relay outputs 2 A / 250 V AC for AC-15 100000 cycles following IEC 60947-5-1 Relay outputs 2 A / 30 V DC for DC-13 150000 cycles following IEC 60947-5-1 |
Analogue input number | 1 |
Analogue input type | PTC1 : PTC temperature probe PTC2 : PTC temperature probe |
Analogue output number | 1 |
Analogue output type | Current output AQ1 : 0...20 mA/4...20 mA , impedance< 500 Ohm Voltage output AQ1 : 0...10 V , impedance> 470 Ohm |
Communication port protocol | Modbus serial RJ45 Modbus serial open style (DO, D1, PE, COM) |
Connector type | 1 RJ45 Open style |
Physical interface | 2-wire RS 485 - connector(s): RJ45 2-wire RS 485 - connector(s): open style (DO, D1, PE, COM) |
Transmission frame | RTU : 1 RJ45 RTU : open style (DO, D1, PE, COM) |
Transmission rate | 4.8…38.4 kbps for Modbus serial RJ45 0.3...115.2 kbps for Modbus serial open style (DO, D1, PE, COM) |
Data format | 8 bits, odd, even or no parity, 1 or 2 bits to stop for Modbus serial RJ45 8 bits, configurable odd, even or no parity for Modbus serial open style (DO, D1, PE, COM) |
Number of addresses | 0…247 for Modbus serial |
Method of access | Slave Modbus serial |
Type of polarization | No impedance for Modbus serial |
Display screen available | True |
Operating position | Vertical +/- 10 degree |
Height | 443 mm |
Width | 206 mm |
Depth | 261.2 mm |
Net weight | 16.50 kg |
internal bypass | True |
Function available | Single direction Pre-heating Power monitoring Condition monitoring User management Ports and services hardening Security event logging Cybersecure firmware update Small motor test |
material declaration | True |
Electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Voltage/current impulse level 3 conforming to IEC 61000-4-5 Damped oscillating waves level 3 conforming to IEC 61000-4-18 Immunity to conducted disturbances radio-frequency level 3 conforming to IEC 61000-4-6 |
---|---|
Pollution degree | Level 3 |
[Uimp] rated impulse withstand voltage | 6 kV |
[Ui] rated insulation voltage | 600 V |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3 |
Ambient air temperature for operation | -25…40 °C (without derating) 40…60 °C (with current derating of 1 % per °C above 40 °C) |
Ambient air temperature for storage | -40…70 °C |
Ambient air transport temperature | -40…70 °C |
Operating altitude | <= 2000 m without derating > 2000...4800 m with current derating 1 % per 100 m above 2000 m |
Relative humidity | 5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
Maximum deflection under vibratory load (during storage) | 1.75 mm at 2...9 Hz |
Maximum deflection under vibratory load (during transport) | 1.75 mm at 2...9 Hz |
Maximum acceleration under vibrational stress (during operation) | 1 gn at 13…200 Hz |
Maximum acceleration under vibratory load (during storage) | 1 gn at 9…200 Hz 1.5 gn at 200…500 Hz |
Maximum acceleration under vibratory load (during transport) | 1 gn at 9…200 Hz 1.5 gn at 200…500 Hz |
Maximum acceleration under shock impact (during operation) | 15 gn at 11 ms |
Maximum acceleration under shock load (during storage) | 10 gn at 11 ms |
Maximum acceleration under shock load (during transport) | 10 gn at 11 ms |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 50.6 cm |
Package 1 Width | 25 cm |
Package 1 Length | 48 cm |
Package 1 Weight | 25.8 kg |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 3 |
Package 2 Height | 61 cm |
Package 2 Width | 60 cm |
Package 2 Length | 80 cm |
Package 2 Weight | 85.9 kg |