EZ9D56810 Schneider Electric Easy9 RCBO 240V - 1P + N - 10A - C curve - 6000 A - 30 mA

EZ9D56810 Schneider Electric Easy9 RCBO 240V - 1P + N - 10A - C curve - 6000 A - 30 mA

Old Price: AED 150.790

New Price: AED 148.750 (1%)


This Easy9 is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+Ns circuit breaker with 10A In rated current and C tripping curve. The earth leakage protection class is A type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A according BS EN 61009-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. This product has an operating test button on the front panel. It also has a fault tripping indication on the front panel by the position of the handle (O-I engraved). This product is compliant with BS EN 61009-1 standard. It has an electrical endurance going up to 4000 cycles and a mechanical endurance going up to 10000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 2. The product color is light grey (RAL 7035). The dimensions are (W) 18mm x (H) 110mm x (D) 72mm. The weight is 180g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C.

RangeEasy9
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameEasy9 RCBO
Poles1P + Ns
Neutral positionLeft
[In] rated current10 A
Earthing systemTN
Network typeCA
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType A
Breaking capacity6000 A Icn at 240 V AC 50 Hz conforming to BS EN 61009-1
Device applicationDistribution
Device location in systemOutgoer
Network frequency50 Hz
[Ue] rated operational voltage240 V AC 50 Hz
Magnetic tripping limit3...5 x In
Residual current tripping technologyVoltage dependent functional earth
Limitation class3
[Ui] rated insulation voltage500 V
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorYes
control typeToggle
Mounting supportCarril DIN
9 mm pitches2
Height110 mm
Width18 mm
Depth72 mm
Net weight180 g
ColourGrey (RAL 7035)
Mechanical durability10000 cycles
Electrical durability4000 cycles 240 V AC 50 Hz
Connections - terminalsTunnel type terminal (top) 25 mm² rigid
Tunnel type terminal (bottom) 16 mm² rigid
Tunnel type terminal (bottom) 16 mm² flexible
Cable (top) 2 cable(s) flexible
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
StandardsBS EN 61009-1
Product certificationsCE
Overvoltage categoryIV
Tropicalisation2
Relative humidity95 % at 55 °C
Ambient air temperature for operation-15…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.5 cm
Package 1 Width9.5 cm
Package 1 Length1.8 cm
Package 1 Weight211 g
Unit Type of Package 2S02
Number of Units in Package 234
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight7174 g
Unit Type of Package 3P12
Number of Units in Package 31088
Package 3 Height70 cm
Package 3 Width120 cm
Package 3 Length80 cm
Package 3 Weight229568 g

 


 

You may also like